Precautions for operating the distilled water machine

Pay attention to the following when using a multi-effect distilled water machine:

1. Ensure that there is enough pure water in the pure water storage tank, and it should be produced in time to ensure the safe operation of the distilled water machine.

2. For the detection of pure water, the results should meet the standard requirements of “GMP”, and the PH value test standard is 5-7, the conductivity test requirement is 2μs/cm or less, and the chloride (Cl-) free chlorine cannot exceed the standard. Test diluted silver nitrate, drop a drop of solution in 100ml of purified water, if there is a white precipitate in pure water, indicating that (Cl-) exceeds the standard, pure water in the tank can not enter the distilled water machine, this regulation must strictly abide by .

3. The pure water pump of the distilled water machine must be drained before starting to ensure the safe operation of the pump.

4. When closing the machine, the feed water valve (MV03) must be closed first. This is mainly to prevent the water in the inlet pipe from flowing back. The high-temperature water is flushed into the glass tube of the flow meter (FS01), which makes the glass burst dangerous.

Note! The operator must operate in strict accordance with the specified operating procedures.

Herb Tea Cut

We provide wide range of herb tea cut, like echinacea tea, nettle leaf tea, dandelion root tea, valerian root tea and red raspberry leaf tea. We can provide blend herbal tea according to formula of customer and we also provide formula according to needs of customers. As one stop shop store of natural ingredients, tea bags like pyramid tea bag and string tea bag can be processed too. Private label is acceptable.