How to deal with problems in the work of Combe brand rolling vacuum packaging machine

1. Vacuum pump oil leakage: There are two reasons for this:
First, due to the oil return valve blockage, only the oil return valve is blocked and cleaned;
Second, the oil window is loose. At this time, after draining the oil, then remove the oil window and wrap the raw material tape or thin plastic film.
2, continuous rolling vacuum packaging machine vacuum pump soot: due to the suction filter blockage or pollution cleaning may lead to the emergence of the real oil pump soot, just replace the exhaust filter; pump oil pollution will also appear too much fumes, replace the new oil Yes; the oil return valve blockage will also produce too much soot, just clean the return valve.
3, continuous rolling vacuum packaging machine does not heat phenomenon, there are many reasons for not heating, mainly: heating strip burn, heating time relay burnout, add burn, control heating AC contactor does not reset, heating transformer is broken, if it appears These phenomena only need to be replaced or reset.
4, continuous rolling vacuum packaging machine heating does not stop, if this phenomenon may be due to poor contact or burnout of the heating time relay, only need to adjust the time relay and socket contact or replacement; control heating AC contactor does not reset will also cause heating Do not stop, we only need to repair or replace.
Although the continuous rolling vacuum packaging machine is simple and practical to operate, once it fails, it will affect the production and bring a lot of disadvantages to the enterprise. Therefore, if there is a fault, it should be dealt with in time, and the repair can be started without any error.